Features
| ∴ |
Easy self-diagnosis by various
loop-back test functions.
( LLB, DLB, ALB,
RDLB) |
| ∴ |
Various testing functions
(BER test) by TPG (Test Pattern Generator) |
| ∴ |
Visual/audible alarm and
status information indication by LEDs. |
| ∴ |
Easy to maintain with operating
terminal access through RS-232. |
| ∴ |
Remote Control function
to reset or change the settings of the device
on the other side |
| ∴ |
2W/4W selectable. |
| ∴ |
Signal quality indication
for the DSL line (S/N margin). |
| ∴ |
Power Consumption: |
| |
1) 220V AC (50Hz) |
| |
2) DC -48V |
| |
3) Incoming power from the
line (2100/4100 only) |
| ∴ |
Low power consumption. |
| ∴ |
Available for various network
topology.
( V.35, DSX (E1) functions) |
| ∴ |
LEDs indicating the signal
status of the DTE side |
Specification
Item |
Specifications |
|
Modulations |
TC-PAM
Modulation |
|
Transmission |
Full-duplex |
|
Line
Type |
2
Wires or 4 Wires |
Loop
Signal |
Line
Speed |
192~2304Kbps/loop |
|
Distance |
7.0km(at
192kbps) |
|
|
2
wire, No noise |
|
Line
Access |
Terminal
Block & RJ45 Modular |
|
Bit
Rate |
Nx64kbps |
Subscriber |
|
(N=1~32) |
Signal |
Interface |
V.35
/ E1 |
|
Clock
Mod |
External,
Internal, Loop |
|
|
220V
(50Hz) |
|
Power |
DC
-48V |
Power |
|
Incoming
power from the line |
|
|
(DC
130, 150, 170V. 2100/4100 only) |
|
Power |
6
watts maximum without line power |
|
Consumption |
20
watts maximum with line power |
Dimensions |
HxWxD
(mm) |
50
x 207 x 300 |
|
|
(2100/4100
only) |
MECHANICAL
Rate(Kbps) |
Reach(Km)
(No noise, 0.4mm twisted pair) |
No
power feeding |
Power
feeding |
2
wire |
4
wire |
2
wire |
4
wire |
64Kbps
- 192Kbps |
6.8Km |
6.8Km
(128Kbps) |
6.3Km |
6.3Km
(128Kbps) |
2304Kbps |
3.6Km |
4.7Km |
3.2Km |
4Km |
SYSTEM
COMPONENT
2100/4100 SERIES
| Rack
Mounted |
 |
-MCU
(Main Control Unit)
· 2RS-232 Port
· System alarm indication LEDs
· Non-volatile memory module
- SHDSL Card
· Selectable wire mode - 2W / 4W
· Two types of interface - E1 / V.35
· Same cards for Rack-mount and Stand-alone
· Power-feeding function
· Line status indication LEDs
· Front switch for Loopback
· Non-volatile memory for configurations
|
| Stand
Alone |
 |
-
Various method for power supply
· AC / DC / No external power(Line power
feeding)
- Two types of interface
· E1: 120 ohm terminal block/
75 ohm BNC
· V.35:N34F
- Easy to maintenance: Plug-in card type
- RS-232 port : MMI operation |
| Repeater |
 |
-
No external power(Line power feeding)
-Transmit up to 12Km with
two repeaters |
Network
Configuration
----------------------------------------------------------------------------------------------------------------
NEXPEED is registered trademark of NexComm Systems Inc. All other trademarks
are property of their respective owners. Specifications are subject to change
without prior notice.
Quality Management
NexComm Systems, Inc has been certified ISO9001 from European Quality
Assurance
Ltd. authorized agent of International Standard Organization(ISO)9001 Quality